Rating
Reviews
Name: Corey Beaudoin
Corey is knowledgeable and completes his work in a timely manner. He has a good attitude and kept me informed at all phases.
great job
Thanks to Corey and Michael for the great service on my furnace. They explained everything that was done.
AC went out over weekend and Corey came out to fix it quickly. He was very knowledgeable and went over all my options. Thanks for getting the house cool again.
Technician was very polite and respectful. He also explained everything and answered all our questions.
Cory does great work.
Response from Grogg's Home Services:
We are happy that Cory did such an amazing job! We will be sure to share your kind words with him!
Called for and issue with water overflowing and drained plug. They were very prompt on turnaround time for services. Our tech Corey was wonderful and professional!
Great service. On time and very knowledgeable
Best in the Business!!!
Corey did awesome at explaining everything we asked him to the best of his knowledge.
Great service
It’s as if Corey knew what the problem was before he got here. Within 15 minutes after arriving he had the unit running. He explained everything he was doing as he done it. Great job.
Performed Platinum Comfort Club Membership Tune-Up on Cooling System Downstairs Larger Unit Customer noted a loud noise when the unit began running, found that the compressor was drawing 15 amps. Found that capacitor had failed for both herm and fan. rated for 70/5 and tested at 66.4/3.91 after cleaning coil and replacing capacitor amp draw on compressor was down to 12.9 Pressures were 118/294 with a 12⁰ subcooling and 19⁰ temperature drop Upstairs Smaller Unit Diagnosed failed blower capacitor. rated for 7.5 and tested 6.1 Performed Platinum Comfort Club Membership Tune-Up on Cooling System
AC repair
Performed Platinum Comfort Club Membership Tune-Up on Cooling System Performed Platinum Comfort Club Membership Tune-Up on Heating System performed combustion analysis, system operating with high levels of CO in exhaust. CO(O) was at 390ppm and climbing. inducer motor pulling .98amps rated for .9. possible restriction in flue, metal flue pipe is plumbed into the chimney, inspected what is accessible and found no obstruction. inducer motor is also extremely noisy. spoke to customer about the age and safety concerns with system. customer said she plans to replace the system before winter. advised customer about financing options.
- Two Safety, Health, and Efficiency Inspections. One furnace and one A/C based on season - 10% Discount off IAQ Additions - 20% Discount off All HVAC Service Repairs - 5% Discount off All New Equipment - FREE Service Call Fees during normal business hours (residential only) - Maintains System Warranty - One night in a hotel on us if left without heat or air - Front of the line service #213 Replacement Media for Aprilaire 4200, 2210, & 3210 Performed Platinum Comfort Club Membership Tune-Up on Cooling System replaced filter, cleaned condenser coil, did not a fair amount of do hair and dust built up on coil. customer declined running furnace at this time due to outdoor temperatures around 90. recommended cozy plus membership for seasonal checkups to avoid needing to kick on heat in the summer. spoke to customer about RGF reme halo, provided information and pricing. Performed Platinum Comfort Club Membership Tune-Up on Cooling System replaced filter, cleaned condenser coil, did
Performed Platinum Comfort Club Membership Tune-Up on Heating System performed combustion analysis, system operating properly with 45 degree temperature rise, 90ppm CO(O) 9.8 O2. cleaned flame sensor, treated condensate pump with dish liquid. drain hose had come loose from drain, secured drain hose into drain. #413 Replacement Media for Aprilaire 4400, 2410, & 3410
cooling maintenance
Emergency AC Service
Emergency AC service
Minisplit Service
AC service
AC service
Emergency AC Service
arrived to find heat pump in low pressure lockout. reset lock out and system attempted 3 times to start and will not stay running for longer than 10 seconds before cutting off. after 3rd attempt system went into high pressure lockoutwith pressure at 160/250. found suction line king valve to be closed. opened valve and reset lockout, system still only runs for 10 seconds before cutting off, pressures now 155/240. customer installed equipment himself, possible refrigerant restriction. checked with management, we will not assure responsibility for the unit and work on the system due to the nature of the installation, being installed by an unlicensed individual will void warranty.
performed maintenance check. evaluated ductwork recommended replacement of duct coordinated with office and gave verbal quote on both flex duct and hard run duct. customer had groundhog in ductwork previously. found multiple holes in supply and crushed return. roughly 60 ft of total ductwork at 14 inch flex.
Description of work performed for Warranty Customer replaced drive board, main board and compressor. system still not operating. checked with tech support. per Trevor at standard air need to replace outdoor unit. part is covered under warranty customer pays labor for current repair, and to replace outdoor unit. per Trey gave customer 10% discounton total bill