AC, Furnace & Plumbing Solutions for Spencer, WV
Since 1970, Grogg’s Home Services has provided professional solutions for Spencer, WV’s heating and cooling needs. Our reputable, local, family-owned business can serve your whole home, bringing you total peace of mind.
We provide a variety of services to keep you at peak comfort:
Heating & Air Conditioning:
- Repair, Installation & Maintenance
- ACs, Furnaces & Heat Pumps
- Geothermal Units
Plumbing:
- Water Heaters
- Drains
- Toilets
- Sinks & Faucets
- Sewage Systems
- Water Filtration
We are located at 1492 E Pike St, Clarksburg, WV 26301.
Phone: (304) 326-0553
We invite you to read some of our reviews below from other residents in the Spencer, WV area to learn more about Grogg’s!
Recent Jobs and Reviews in Spencer, WV
Our Local Reviews by City
- 1, WV (2)
- Athens, OH (5)
- Belleville, WV (9)
- Belmont, WV (13)
- Belpre, OH (105)
- Belpre Township, OH (2)
- Beverly, OH (2)
- Big Bend, WV (1)
- Big Springs, WV (3)
- Blennerhassett, WV (1)
- Bridgeport, WV (118)
- Brownton, WV (1)
- Buckhannon, WV (15)
- Center Point, WV (1)
- Chesterhill, OH (1)
- Clarksburg, WV (95)
- Clay, WV (3)
- Coolville, OH (10)
- Core, WV (1)
- Cottageville, WV (2)
- Coxs Mills, WV (1)
- Cutler, OH (4)
- Davisville, WV (21)
- De Kalb-Troy, WV (1)
- Elizabeth, WV (15)
- Elkins, WV (1)
- Ellenboro, WV (1)
- Evans, WV (1)
- Fairmont, WV (52)
- Fleming, OH (1)
- Flemington, WV (4)
- Glenville, WV (2)
- Grafton, WV (8)
- Grantsville, WV (7)
- Guysville, OH (1)
- Hackers Creek-Skin Creek, WV (1)
- Harrisville, WV (8)
- Hockingport, OH (3)
- Horner, WV (1)
- I, WV (1)
- Jane Lew, WV (5)
- Kincheloe, WV (1)
- Little Hocking, OH (16)
- Lost Creek, WV (12)
- Lowell, OH (2)
- Lubeck, WV (2)
- Lumberport, WV (2)
- Mannington, WV (4)
- Marietta, OH (77)
- McConnelsville, OH (1)
- Meadowbrook, WV (2)
- Millwood, WV (6)
- Mineral Wells, WV (45)
- Moatsville, WV (4)
- Morgantown, WV (13)
- Mount Clare, WV (17)
- New Martinsville, WV (1)
- New Milton, WV (2)
- Newport, OH (3)
- North Hills, WV (2)
- Nutter Fort, WV (8)
- Paden City, WV (1)
- Parkersburg, WV (456)
- Pennsboro, WV (16)
- Philippi, WV (4)
- Portland, OH (1)
- Pullman, WV (1)
- Rachel, WV (1)
- Ravenswood, WV (54)
- Reno, OH (1)
- Reynoldsville, WV (4)
- Ripley, WV (5)
- Rivesville, WV (2)
- Rock Cave, WV (3)
- Rockport, WV (2)
- Saint Marys, WV (36)
- Salem, WV (17)
- Sandyville, WV (6)
- Second, WV (2)
- Shinnston, WV (20)
- Sistersville, WV (1)
- Smithville, WV (1)
- SOMERVLLE FRK, WV (1)
- South Urban, WV (1)
- Southern, WV (1)
- Spelter, WV (1)
- Spencer, WV (8)
- Stockport, OH (1)
- Stonewood, WV (5)
- Summit Point, WV (1)
- Sutton, WV (1)
- Tallmansville, WV (2)
- Union, WV (1)
- Vienna, WV (225)
- Vincent, OH (29)
- Walker, WV (18)
- Walkersville, WV (1)
- Wallace, WV (1)
- Washington, WV (112)
- Waterford, OH (2)
- Waverly, WV (22)
- West Augusta, WV (2)
- West Union, WV (5)
- Weston, WV (11)
- Williamstown, WV (95)
- Wolf Summit, WV (1)
Job Locations and Reviews
It didn’t take long for Alex to find the reason for our AC outage. The culprits turned out to be a couple of insects which kept the switch from making contact. We sure want to thank you again, Alex, for getting our house back to a cool temperature.s
It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.
Customer said ac would not come on. Arrived and turned on stat. Blower came on but ac did not. Verified 240V to ac. Found a bug wedged in the contactor causing it to not fully close and complete the circuit. Removed bug. Tested and verified good contactor. Ac came on. Confirmed operation.
It is always a pleasure to deal with Alex. He was able to adjust the airflow on the furnace/air conditioner and solve the problem. Very best to all the folks at Grogg’s!
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.
Customer said cooling was louder than before. Checked airflow in both heating and cooling. Could not lower heat speed anymore to try and get as much heat away as possible to avoid igniter wire melting. Lowered cooling speed to speed tap 3 medium high 1079 cfm to help quiet blower. Temp drop is within manufacturer spec. Informed customer of changes to service area and pricing.
Low ambient Control module and fan blade. Installed new parts. Verified operation. Fan is modulating. 24 degree temperature drop.
Replaced broken fan motor and out of range capacitor. Module is also bad. Ordered and needed to return.
Ac was not working. Installer disconnected thermostat wire and balled it up. Hooked new furnace back into the ring stat. Moved new stat into the correct room and hooked up the correct wire. Also installer left the breaker off (was not tripped). Turned breaker on. Verified operation.
Alex very quickly was able to find a short circuit in the furnace and repair the problem.
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
Furnace was tripping breaker and not running. Opened breaker box to confirm no loose wires. Furnace wire was in good condition. Thermostat was set to below room temperature. Customer wanted a simpler stat. Installed aa8444 for customer. Furnace would not ignite. Confirmed 120 volts to the igniter. Opened burner compartment to find igniter wire melted and shorted to metal. Swapped out igniter. Tried to position wire where it did not touch anything. Watched it light a couple times and watched 1 heating cycle. Confirmed operation.
When our furnace quit working, we called Groggs and they sent Shawn right over. In a little while, he had the furnace working again. Many thanks to Shawn!
Thank you for the wonderful review and for taking the time to share your feedback.
Weekend service
Estimate - P
Commercial Service Fee Two systems experiencing problems. Lab unit, York located above the break room. Two leaks on liquid and suction lines at the condensing unit. Charged the system up with 2 lbs of R410a Trey and Jim will be putting together a quote for options. Transformer/power room unit carrier. Coil has developed a leak, froze over. Thawed the coil out and charged the system up with 4 lbs R419a to get it running for the time being. Quote for a new evaporator coil for the carrier unit will be roughly $2400.00-$2600.00 Please notify the office if or when you want it done. Per maintenance department the new system for the training room has been working perfectly.
19 year old Goodman package unit model PGB036100-1A. The inducer motor has burnt wiring from over amping and needs to be replaced. Checked the gas valve and found high resistance on the coil, the gas valve needs replaced. Checked the heat exchanger and located a crack in it. The heat exchanger needs replaced. The blower assembly is dirty and needs cleaned. Checked refrigerant pressure and found them to be low. Inspected for signs of leaks and found refrigerant oil on the evaporator coil. Coil needs replaced. Cost of repair is $8,268.11 Recommend replacement of the equipment.
Grogg's 1 year visit
Performed anniversary check on equipment. Cleaned washable filter. Verified working status of surge protection. All checks good. Discussed comfort club with customer.
Always very satisfied with Groggs' service. They are quick to respond to our calls when we need help. We have no complaints with this company.
Commercial Service Fee Unit for the lab: Insulation inside air handler had fallen over the evaporator coil and low on refrigerant. Addressed both issues and unit performance within range. Leaking either indoor coil Or outdoor coil, will have to let it run till is noticeable so diagnosis on parts are accurate. For now it’s operating.
Performed Platinum Comfort Club Membership Tune-Up on Cooling System Both units running properly on cooling mode. Heating maintenance will be done in the fall. I am attaching a quote for a whole home dehumidifier. Will talk to management to best identify location.
Commercial Service Fee Bad dual capacitor was keeping the fan from operating properly along with a damage contactor. (Melted from a loose connection) Replaced both, tested operation, fan is pulling good amps 1.01. Pressures 140/350
Capacitor for geo was bad. Run and común were loose at contactor perhaps caused wires to over heat and take capacitor out. Found unit calling for cooling with extremely hot compressor. In the future please turn system off if it is not operating properly to prevent extended failure on other parts. Water pressure drop within range.
Fujitsu on the left side of the training room is out of refrigerant, leak is located on the back of the unit on the suction line. Will create a quote for the repair, and return with the necessary supplies. Second unit on the right side is a Klimaire mini split and the condenser is located inside of the building which is what has caused much of the failures. Unit is missing the remote, both evaporator and condenser coil is packed with dirt. To get to a point where we could even appropriately test it would cost roughly $1000.00. Second unit should be replaced and condenser relocated to the roof like the Fujitsu. Will discuss pricing and replacement options with management.
Commercial Service Fee Furnace is extremely dirty, black dust covering everything. Fuse was blown and refrigerant charge was low. Charged the system, tested operation, unit is performing as well as it can for its age and condition.
HVAC furnace evaluation
Service for water expansion tank and the watts pressure and temperature relief valve.
frendly and knowledgeable
Fred was very knowledgeable and friendly. Fair prices and will call again.
Thank you so much for your amazing feedback on Fred and confidence in our services. Be sure to keep in mind all of our services. Please don't keep us a secret
