Grogg’s happy to be one of the largest and most successful heating and air conditioning companies in Lost Creek, WV.
See how we’ve earned our five-star status in Lost Creek, WV by viewing our heating and air conditioning reviews below.
Local Reviews
for Lost Creek, WV
Our Reviews by City
Great
Busch - Lost Creek, WV
Wonderful I will be using them again
Great
Poth - Lost Creek, WV
Propmt thorough service Accommodating when i was without heat. Very much appreciated!
Quick and thorough
Barnes - Lost Creek, WV
Grogg's came and set up our system for the fall and next Spring quickly and thoroughly. I was impressed by the texts sending me a picture of the tech and updates on how close they were to my house. Very impressed.
Excellent Service
Clutter - Lost Creek, WV
John is an excellent technician. Very thorough, professional and courteous
Dependable service
Clutter - Lost Creek, WV
I’m pleased
Mendez - Lost Creek, WV
no problem
Ward - Lost Creek, WV
Response from Grogg's Heating & Air Conditioning, Inc. (Parkersburg):
Thank you so much for your amazing feedback and confidence in our services. Be sure to keep in mind all of our services. Please don't keep us a secret
Very Professional and Thorough
Chris - Lost Creek, WV
I have had a service contract with Groggs for years to take care of my HVAC. They're responsive, thorough and very professional. When I've needed them to come and fix something, I never have had to wait more than a few hours at most. If it wasn't for Grogg's, I'd be lost. No other service here can deliver this level of quality.
Response from Grogg's Heating & Air Conditioning, Inc. (Parkersburg):
Thank you so much for your five star review. We hope you consider Grogg’s in the future for all your home Services needs.

James S.
Includes all miscellaneous materials and labor to completely install. For Heat Exchanger Only: $679.00

Greg P.
Adjusted blower delay from 90 to 120, furnace operating properly at this time.

Greg P.
Unit rollout switch was open, reset, found furnace to have flames rolling out when blower kicks on, heat exchanger is compromised, requires heat exchanger/collector box replacement, or unit replacement. Current unit is 2003 model. Heat exchanger was replaced once in 2013, part would still be under warranty, quoted repairs for labor.

Greg P.
Replaced control board, ok at this time.

Greg P.
Found unit to have no charge, leaking at suction connection on indoor unit. Repaired leak, pulled vacuum, weighed in factory charge, ok at this time.

Greg P.
Trane ecm motor

Greg P.
Performed platinum maintenance check, ok at this time. Customer said unit was shutting off, previous fault code was for pressure switch, checked vent, cycled unit, no issues at this time.

Greg P.
Cycled furnace, checked heat exchanger, furnace heating properly at this time. Customer said fan had came on with no call. Control board has corrosion, will need replacement.

John K.
Customer canceled

Greg P.
Power is off to stat until repairs are made

Greg P.
Blower motor will need replaced. Cannot diagnose further until blower is replaced.

Greg P.
Same outdoor unit was popping fuse, disconnected for now, will need to schedule 2 techs to return and replace 2 wire to ac for that unit.

Greg P.
Unit had went off on moisture fault, no water present, will order new drain pan sensor

John K.
Service checked over system found no problems system operating properly at this time.

Greg P.
Ptu on furnace, no issues at this time.

Greg P.
Found that gas valve was not receiving 24v, replaced only control board, furnace operating properly at this time.

John K.
Platinum service tune up heating and cooling system operating properly at this time.

John K.
When I was in crawl space earlier in the day I knocked off a supply line which feed the truck line fixed and system operating properly at this time.

John K.
Platinum service tune up heating and cooling found fan motor failing ordering replacement.

Greg P.
Replaced contactor, unit operating properly at this time.

Brian S.
Hvac Installation Helper James Savina

Greg P.
Twinned systems in attic tripping low voltage fuse, traced fault to be from one of the outdoor units. Disconnected low volt wiring from that unit, furnaces and other ac came on ok. Ohmed wire to outdoor unit, no issue found. Traced and ohmed low voltage wiring in outdoor unit, no issues found. Will need to get 3 pull 24v contactor for that unit. No other reasons found for it to blow fuse.

Greg P.
Ac condenser fan motor bad, needs replaced. Customer will pay service fee, and advise if needs motor ordered.

John K.
Drain line clogged back up cleared and poured bleach in it system operating properly at this time.

Greg P.
Cleared drain line, performed platinum maintenance check, gas valve not opening, need to order. Also found capacitor outside failing, replaced. Cooling properly at this time. Will order gas valve