The professional team at Grogg’s Home Services has provided the residents of Ellenboro, WV with exceptional services since 1970! We are proud to offer great workmanship paired with affordable prices for all of your most important home comfort services. Make sure to call Grogg’s first for your air conditioner, heater, plumbing and window needs! Our services include repairs, installations and maintenance on heating, cooling, plumbing, windows and more that go above and beyond, every time.

You won’t find another company around with better reviews than ours! We invite you to read some of them below and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Ellenboro, WV.

Recent Jobs and Reviews in Ellenboro, WV

Rated 5.0 out of 5 stars based on 1 customer reviews

Our Local Reviews by City

Job Locations and Reviews

Epson E.
Epson E. Checked in
2011 Lennox ac low on refrigerant and bad capacitor. Customer expressed that unit was recharged a couple years ago. Informed customer about the options for leak search, cost to replace a coil out of warranty as well as charging the system or/and replacing. Customer decided to replace capacitor and charge the unit. Aware that it’s hard to tell how long it will run before gets low again. Left unit with new capacitor, clean condenser, and super heat within range.
Ellenboro, WV 26346
Travis W.
Travis W. Checked in
Cleaned and checked operation of equipment. Installed surge protection and found no issues with system.
Ellenboro, WV 26346
Travis W.
Travis W. Checked in
Performed maintenance on equipment. Changed 16-25-1 filter. AC thermostat wires were pinched going into the furnace. Loosened connection and system kicked on. All checks were good.
Ellenboro, WV 26346
John B.
John B. Checked in
Thermostat wiring was a mess behind stat that had g and c wires crossed and touching causing a short when call for cool was present. Shortened wires and secured them neatly. Replaced stat and tested system for proper operation. Customer was curious about indoor air quality products and requested some quotes which I provided.
Ellenboro, WV 26346
Shawn L.
Shawn L. Checked in
YORK furnace
Ellenboro, WV 26346
John B.
John B. Checked in
Concern customer had was the blowers never shut off after heat demand was satisfied. Found that both thermostats fan option was set to on instead of auto. Switched fan setting to auto to correct issue. Two 1994 80% bard gas furnaces. Combustion analysis tested fine on units but efficiency has dropped to 77%. Units are past their life expectancy and showing their age. Customer has requested an appointment to get pricing for new equipment. Estimate is scheduled December 22 from 9-11am.
Ellenboro, WV 26346
Chris D.
Chris D. Checked in
Corrected the issue, system is performing great, and explained any questions about thermostat operation. Technician Christopher Dehnart
Ellenboro, WV 26346
Ellenboro, WV - Commercial Service Fee
Error code for open pressure switch.  
Resolved by removing two birds and a nest from the exhaust and inducer assembly.

Condensate pump is cracked and should be replaced and the TXV needs Re-insulated.  Customers gas provider is being contacted about the gas pressure dropping out, but after that is corrected, both systems should have a maintenance done to set the correct gas pressures.

The inside of the heat exchanger is black with soot.
This is a indication of a bad gas to oxygen ratio which is directly linking to gas pressure, if this is not adjusted in before use each year it will have a big impact on the life of the system as that build up of residue is acidic and will eat through the heat exchanger.

Technician Christopher Dehnart

Please include your tax exempt number when you call or mail in payment.
Chris D.
Chris D. Checked in
Commercial Service Fee Error code for open pressure switch. Resolved by removing two birds and a nest from the exhaust and inducer assembly. Condensate pump is cracked and should be replaced and the TXV needs Re-insulated. Customers gas provider is being contacted about the gas pressure dropping out, but after that is corrected, both systems should have a maintenance done to set the correct gas pressures. The inside of the heat exchanger is black with soot. This is a indication of a bad gas to oxygen ratio which is directly linking to gas pressure, if this is not adjusted in before use each year it will have a big impact on the life of the system as that build up of residue is acidic and will eat through the heat exchanger. Technician Christopher Dehnart Please include your tax exempt number when you call or mail in payment.
Ellenboro, WV 26346
Ellenboro, WV - Performed Platinum Comfort Club Membership Tune-Up on Heating System
2021 Ruud heat pump system w/ AA213 filter. Replaced filter. Backup heat is propane. All checks good at this time
Matthew G.
Matthew G. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Heating System 2021 Ruud heat pump system w/ AA213 filter. Replaced filter. Backup heat is propane. All checks good at this time
Ellenboro, WV 26346
Greg C.
Greg C. Checked in
Ellenboro, WV 26346
Ellenboro, WV - Service Call Platinum Client: Ductless unit in the IT room had a fault code for discharge temperature error. Checked the refrigerant pressure and found it to be low. Checked the flare fittings in the IT room for leaks and they were good. Found a leaking valve core on the suction valve outside at the condenser unit. Tightened valve and verified it was no longer leaking. Added 3 pounds of 410a refrigerant. Checked refrigerant pressure and temperatures. Everything checks out good. Delta T of 20 degrees inside the IT room. No further action needed at this time.
Shawn L.
Shawn L. Checked in
Service Call Platinum Client: Ductless unit in the IT room had a fault code for discharge temperature error. Checked the refrigerant pressure and found it to be low. Checked the flare fittings in the IT room for leaks and they were good. Found a leaking valve core on the suction valve outside at the condenser unit. Tightened valve and verified it was no longer leaking. Added 3 pounds of 410a refrigerant. Checked refrigerant pressure and temperatures. Everything checks out good. Delta T of 20 degrees inside the IT room. No further action needed at this time.
Ellenboro, WV 26346
Ellenboro, WV - Service Call Fee:
Upon inspection found unit very low on refrigerant customer stated they had another company put stop leak and a pound and a half of refrigerant beginning of week that has already leaked out. Suggested a new system.
Doug H.
Doug H. Checked in
Service Call Fee: Upon inspection found unit very low on refrigerant customer stated they had another company put stop leak and a pound and a half of refrigerant beginning of week that has already leaked out. Suggested a new system.
Ellenboro, WV 26346
Ellenboro, WV - Service Call Platinum Client- replaced failed capacitor on 17yr old ac unit. System has high head pressure (400psi). Unable to clean unit condenser coil today due the the water being shut off(water company is working on the water lines down the street). Set customer up on maintenance plan so the unit can be cleaned at a later date when maintenance is scheduled. Furnace is 27 yrs old and is showing it age. Blower motor is getting caked with dirt.
John B.
John B. Checked in
Service Call Platinum Client- replaced failed capacitor on 17yr old ac unit. System has high head pressure (400psi). Unable to clean unit condenser coil today due the the water being shut off(water company is working on the water lines down the street). Set customer up on maintenance plan so the unit can be cleaned at a later date when maintenance is scheduled. Furnace is 27 yrs old and is showing it age. Blower motor is getting caked with dirt.
Ellenboro, WV 26346
Lee B.
Lee B. Checked in
Ellenboro, WV 26346
Ellenboro, WV - Examined system and found no issues. Filter size 20-25-1. Tested system in cooling and heat mode and was able to get both to work properly.
Travis W.
Travis W. Checked in
Examined system and found no issues. Filter size 20-25-1. Tested system in cooling and heat mode and was able to get both to work properly.
Ellenboro, WV 26346
Ellenboro, WV - Performed Platinum Comfort Club Membership Tune-Up on Heating System. Performed maintenance on (4) 2009 Carrier Affinty split systems, and (1) mini split system with (1) head unit to cool server room. Note: systems use 55/6 capacitors for outdoor units, w/ 24x24x4 filters being used in a 5” wide filter casing if that size is more attainable. Systems are marked by number on filter slots, with system #4 having a flooded inducer caused by plugged drain. Cleared drain/trap/inducer. One system has a Honeywell direct intake steam humidifier. Adjusted Cozy plan from 1system to 5systems.
Matthew G.
Matthew G. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Heating System. Performed maintenance on (4) 2009 Carrier Affinty split systems, and (1) mini split system with (1) head unit to cool server room. Note: systems use 55/6 capacitors for outdoor units, w/ 24x24x4 filters being used in a 5” wide filter casing if that size is more attainable. Systems are marked by number on filter slots, with system #4 having a flooded inducer caused by plugged drain. Cleared drain/trap/inducer. One system has a Honeywell direct intake steam humidifier. Adjusted Cozy plan from 1system to 5systems.
Ellenboro, WV 26346
Chris D.
Chris D. Checked in
Ellenboro, WV 26346
Ellenboro, WV - Service Call Fee: Adjusted Water Pressure Regulator and Put Proper Air Pressure in Thermal Expansion Tank.
John T.
John T. Checked in
Service Call Fee: Adjusted Water Pressure Regulator and Put Proper Air Pressure in Thermal Expansion Tank.
Ellenboro, WV 26346
Ellenboro, WV - THERM-X-TROL POTABLE WATER EXPANSION TANK
Matthew R.
Matthew R. Checked in
THERM-X-TROL POTABLE WATER EXPANSION TANK
Ellenboro, WV 26346
Greg C.
Greg C. Checked in
Ellenboro, WV 26346
Ellenboro, WV - MAINTENANCE
Travis W.
Travis W. Checked in
MAINTENANCE
Ellenboro, WV 26346
John B.
John B. Checked in
HVAC Maintenance
Ellenboro, WV 26346
Greg C.
Greg C. Checked in
adding 2 6 inch supplies in back room
Ellenboro, WV 26346
Frank  M.
Frank M. Checked in
Rooftop
Ellenboro, WV 26346
Fred E.
Fred E. Checked in
Arrived and found inducer capacitor failed. Replaced and system fired off. Checked system and it is operating properly at this time. Will need (12) 16x25x2 filters. Also have tax exempt forms.
Ellenboro, WV 26346
Review
Frederick was great, he was quick and efficient, courteous and took the time to explain everything he did for us. I am very pleased.
Ellenboro - Ellenboro, WV 26346
Response from Grogg's Home Services:

Thank you for the great review on Fred and your confidence in our services. Please consider us for all your Home Services needs. Don't keep us a secret.

Undeniably Good Reviews SINCE 1970

The last home service provider you'll ever need!

Request Appointment 
Gravity Forms Pagination Must be Steps