Bridgeport WV Heating, AC Repair & Plumber

The professional team at Grogg's Home Services has provided the residents of Bridgeport, WV with exceptional services since 1970! We are proud to offer great workmanship paired with affordable prices for all of your most important home comfort services. Make sure to call Grogg's first for your air conditioner, heater, plumbing and window needs! Our services include repairs, installations and maintenance on heating, cooling, plumbing, windows and more that go above and beyond, every time.

You won't find another company around with better reviews than ours! We invite you to read some of them below and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Bridgeport, WV.

What are the benefits of an HVAC maintenance plan?

Some of the benefits of an HVAC maintenance plan are:

  • Your HVAC system lasts longer
  • Your energy bills are lower
  • Your HVAC system breaks down less often

Another benefit of maintenance plans are the discounts and perks it provides. Most maintenance plans offer discounts on repairs and service calls, making repairs more affordable when they do arise. To get your HVAC unit on a maintenance plan, contact us today.

How long does it take to service my home HVAC system near Bridgeport, WV?

It takes around one hour to service your home HVAC system in Bridgeport, WV. Although, it may take longer if the HVAC technician finds an issue with your HVAC system that needs to be addressed. Generally, if the HVAC technician finds a problem  with your HVAC unit, they can provide you with a quote for the repair and they may have availability to repair it the same day. To learn more about getting your HVAC system serviced and on a maintenance plan, contact us today.

How often should you replace your HVAC system near Bridgeport, WV?

You should have your HVAC system replaced every 10-15 years in Bridgeport, WV. However, you may want to replace your HVAC system sooner if:

  • Your energy bills have increased
  • Your HVAC system doesn't work properly
  • Your HVAC system breaks down frequently

One of the best ways to ensure that your HVAC system lasts its full life expectancy is to have it serviced regularly. Regular maintenance of your HVAC unit enables it to run smoother and last longer. To get your HVAC system replaced or on a maintenance plan, contact us.

Recent Jobs and Reviews in Bridgeport, WV

Rated 4.9 out of 5 stars based on 118 customer reviews

Bridgeport, WV at a glance

Grogg's Heating & Air Conditioning, Inc. has completed 25 jobs in Bridgeport, WV in June 2022.

The most recent job was on June 13, 2022.

Grogg's Heating & Air Conditioning, Inc. completed its first job in Bridgeport, WV in June 2019.

Our Local Reviews by City

Job Locations and Reviews

Bridgeport, WV - did find one of the wires unknown to thermostat to be broke somewhere in wall. system has a verybodd zoning realy board with booster motor added . system is from 2003 and heat exchanger is failed did set up quote to replace.
Kyle P.
Kyle P. Checked in
did find one of the wires unknown to thermostat to be broke somewhere in wall. system has a verybodd zoning realy board with booster motor added . system is from 2003 and heat exchanger is failed did set up quote to replace.
Bridgeport, WV 26330
Matthew S.
Matthew S. Checked in
Bridgeport, WV 26330
Bridgeport, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
Upon inspection found outside unit is low on refrigerant. I also checked minisplit and found no noise at this time
Doug H.
Doug H. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System Upon inspection found outside unit is low on refrigerant. I also checked minisplit and found no noise at this time
Bridgeport, WV 26330
Bridgeport, WV - Service Call Platinum Client

diagnosed system low on refrigerant and has failed capacitor on heat pump. found leak in evaporator coil. 

system is covered by 10 year parts and labor. customer would like to proceed with warranty evaporator coil replacement and recharge the system to get it running for the mean time. 

ordering warranty coil from manufacturer. added 11 lbs obtaining normal refrigerant pressures 119/240. 

signed customer up on cozy maintenance plan
Corey B.
Corey B. Checked in
Service Call Platinum Client diagnosed system low on refrigerant and has failed capacitor on heat pump. found leak in evaporator coil. system is covered by 10 year parts and labor. customer would like to proceed with warranty evaporator coil replacement and recharge the system to get it running for the mean time. ordering warranty coil from manufacturer. added 11 lbs obtaining normal refrigerant pressures 119/240. signed customer up on cozy maintenance plan
Bridgeport, WV 26330
Corey B.
Corey B. Checked in
AC repair
Bridgeport, WV 26330
Kyle P.
Kyle P. Checked in
Bridgeport, WV 26330
Kyle P.
Kyle P. Checked in
Bridgeport, WV 26330
Bridgeport, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
07 Carrier split system w/ 16x25x1 filter. All checks good at this time. No sign of refrigerant issue however just to note, customer mentioned a liquid sealant pushed through the lines in the past to fix an old leak. Discussed operation of Honeywell programmable tstat. At some point in past it had reset to factory settings plus misunderstandings of between hold/temporary options. Device is working properly now.
Matthew G.
Matthew G. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System 07 Carrier split system w/ 16x25x1 filter. All checks good at this time. No sign of refrigerant issue however just to note, customer mentioned a liquid sealant pushed through the lines in the past to fix an old leak. Discussed operation of Honeywell programmable tstat. At some point in past it had reset to factory settings plus misunderstandings of between hold/temporary options. Device is working properly now.
Bridgeport, WV 26330
Bridgeport, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
2021 Ruud a/c and 2002 ICP furnace using 16x25x1 filter. Found 7.5 mfd blower motor low out of range, homeowner elected to replace themself. Ran test with new one in, getting good readings. All other checks good at this time.
Matthew G.
Matthew G. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System 2021 Ruud a/c and 2002 ICP furnace using 16x25x1 filter. Found 7.5 mfd blower motor low out of range, homeowner elected to replace themself. Ran test with new one in, getting good readings. All other checks good at this time.
Bridgeport, WV 26330
Bridgeport, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
2 systems
Downstairs: 2006 Trane split system w/ 16x25x1 filter. 

Upstairs: 2006 Trane split system w/ 16x25x1 filter.

Cap sizes are 45/5 and 40/5. All checks good at this time, systems use r-22 refrigerant. Given age of units and refrigerant type, although no signs of immediate issue this visit, units are starting to show their age and wear. Advise continued maintenance plan to monitor until potential near future system replacement.
Matthew G.
Matthew G. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System 2 systems Downstairs: 2006 Trane split system w/ 16x25x1 filter. Upstairs: 2006 Trane split system w/ 16x25x1 filter. Cap sizes are 45/5 and 40/5. All checks good at this time, systems use r-22 refrigerant. Given age of units and refrigerant type, although no signs of immediate issue this visit, units are starting to show their age and wear. Advise continued maintenance plan to monitor until potential near future system replacement.
Bridgeport, WV 26330
Bridgeport, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
2004 Rheem a/c check w/ AA413 filter. Replaced filter and washed dehumidifier filter. Cleared drains and cleaned condenser coil. System is currently operating as best it can given its age, however although still in range, amp draws show to be on the high side of range. Capacitor rated for 45/5 reading at 35mfd on compressor. Quote cap for now, homeowners will speak with comfort advisor Friday for replacement options first to decide if repair will be needed. CUSTOMER WOULD LIKE PHYSICAL COPY OF INVOICE FOR TODAY MAILED PLEASE FOR THEIR OWN RECORDS.
Matthew G.
Matthew G. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System 2004 Rheem a/c check w/ AA413 filter. Replaced filter and washed dehumidifier filter. Cleared drains and cleaned condenser coil. System is currently operating as best it can given its age, however although still in range, amp draws show to be on the high side of range. Capacitor rated for 45/5 reading at 35mfd on compressor. Quote cap for now, homeowners will speak with comfort advisor Friday for replacement options first to decide if repair will be needed. CUSTOMER WOULD LIKE PHYSICAL COPY OF INVOICE FOR TODAY MAILED PLEASE FOR THEIR OWN RECORDS.
Bridgeport, WV 26330
Bridgeport, WV - found drain clogged on upstairs unit did unclog drain ,did find bad blower capacitor on downstairs unit 
did find both run start capacitors to be failed on both outdoor units did replace both, capacitors failed due to outdoor units being extremely dirty did do maintenance on both outdoor units cleaned coils checked amp draws and pressures. however the unit supplies the downstairs has a approximately 8 inch hole are out of coil from dog urine coil, tubing completely exposed as well. unit is hovering above freezing (34 degrees) and is low of refrigerate did see oily residue around hole. did verbaly quote out of warranty outdoor coil (manufacturer will not cover a coil where an animal caused it to leak ) customers chose to get estimate on replacing unit.
Kyle P.
Kyle P. Checked in
found drain clogged on upstairs unit did unclog drain ,did find bad blower capacitor on downstairs unit did find both run start capacitors to be failed on both outdoor units did replace both, capacitors failed due to outdoor units being extremely dirty did do maintenance on both outdoor units cleaned coils checked amp draws and pressures. however the unit supplies the downstairs has a approximately 8 inch hole are out of coil from dog urine coil, tubing completely exposed as well. unit is hovering above freezing (34 degrees) and is low of refrigerate did see oily residue around hole. did verbaly quote out of warranty outdoor coil (manufacturer will not cover a coil where an animal caused it to leak ) customers chose to get estimate on replacing unit.
Bridgeport, WV 26330
Corey B.
Corey B. Checked in
Maintenance
Bridgeport, WV 26330
Allen W.
Allen W. Checked in
Bridgeport, WV 26330
Greg C.
Greg C. Checked in
Bridgeport, WV 26330
Bridgeport, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
2009 Carrier split system w/ 16x25x1 filter. All cooling checks good at this time.
Matthew G.
Matthew G. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System 2009 Carrier split system w/ 16x25x1 filter. All cooling checks good at this time.
Bridgeport, WV 26330
Bridgeport, WV - Service No Charge
did find very dirty filter sucked up against the blower. did remove filter and run system. found system to be low on refrigerate did add approximately 1 lbs of r410a. however the condenser is extremely dirty and their is no hose hookup indoor or outdoor tried multiple locations all wrong size. customer did say she will get her maintenance guys to clean the unit. the outdoor and indoor unit are in poor condition outdoor unit appears  have hit with lawn mower did recommend replacing unit, customer declined at this time.
Kyle P.
Kyle P. Checked in
Service No Charge did find very dirty filter sucked up against the blower. did remove filter and run system. found system to be low on refrigerate did add approximately 1 lbs of r410a. however the condenser is extremely dirty and their is no hose hookup indoor or outdoor tried multiple locations all wrong size. customer did say she will get her maintenance guys to clean the unit. the outdoor and indoor unit are in poor condition outdoor unit appears have hit with lawn mower did recommend replacing unit, customer declined at this time.
Bridgeport, WV 26330
James S.
James S. Checked in
Bridgeport, WV 26330
Bridgeport, WV - Service Call Platinum Client

breaker for minisplit had tripped, customer experienced a power outage yesterday and minisplit did not come back on after. 
customer attempted to reset breaker. 

breaker was tripped but in the on position. turned breaker off and then back to on. system powered on and is operating normally, inspected wiring connections, tested circuit. minisplit is pulling 6 amps. 

advised customer that a power surge may be the cause. advise having surge protection on minisplit. quoted pricing. customer declined at this time.
Corey B.
Corey B. Checked in
Service Call Platinum Client breaker for minisplit had tripped, customer experienced a power outage yesterday and minisplit did not come back on after. customer attempted to reset breaker. breaker was tripped but in the on position. turned breaker off and then back to on. system powered on and is operating normally, inspected wiring connections, tested circuit. minisplit is pulling 6 amps. advised customer that a power surge may be the cause. advise having surge protection on minisplit. quoted pricing. customer declined at this time.
Bridgeport, WV 26330
Bridgeport, WV - Service Call After Hours Fee

found 5 microfarad capacitor for condenser fan motor to be completely failed replaced capacitor condenser fan motor started, system operating refrigerant pressures 62 / 200, advise customer that system is low on R22. system is a 2005 Linux in poor condition. advise that customer prepare to replace the system, furnace is the same age as the AC. customer declined adding refrigerant at this time spoke to customer about maintenance plan customer declined at this time
Corey B.
Corey B. Checked in
Service Call After Hours Fee found 5 microfarad capacitor for condenser fan motor to be completely failed replaced capacitor condenser fan motor started, system operating refrigerant pressures 62 / 200, advise customer that system is low on R22. system is a 2005 Linux in poor condition. advise that customer prepare to replace the system, furnace is the same age as the AC. customer declined adding refrigerant at this time spoke to customer about maintenance plan customer declined at this time
Bridgeport, WV 26330
Bridgeport, WV - Service Call Platinum Client
drain was partially clogged did clear with nitrogen. however possibly cracked drain pan didnslope drain better but couldn't see a Crack system is draining properly at this time
Kyle P.
Kyle P. Checked in
Service Call Platinum Client drain was partially clogged did clear with nitrogen. however possibly cracked drain pan didnslope drain better but couldn't see a Crack system is draining properly at this time
Bridgeport, WV 26330
Bridgeport, WV - THERM-O-DISK SEQUENCER
Doug H.
Doug H. Checked in
THERM-O-DISK SEQUENCER
Bridgeport, WV 26330
Bridgeport, WV - Service Call Fee:

diagnosed system low on refrigerant also has failed dual capacitor 60 and 5 tested at 8.1. customer pointed out oil on line set confirmed hole solder connection. quoted customer to repair leak and recharge system, factory charge with 7.1lb

quoted customer approximately 1200 to 1,400 to repair. customer decided he would like to check with the company that installed it and get a second quote for repair. left disconnect turned off had already closed off service valves.
Corey B.
Corey B. Checked in
Service Call Fee: diagnosed system low on refrigerant also has failed dual capacitor 60 and 5 tested at 8.1. customer pointed out oil on line set confirmed hole solder connection. quoted customer to repair leak and recharge system, factory charge with 7.1lb quoted customer approximately 1200 to 1,400 to repair. customer decided he would like to check with the company that installed it and get a second quote for repair. left disconnect turned off had already closed off service valves.
Bridgeport, WV 26330
Bridgeport, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System

condenser coil is very dirty. cleaned coil. 
inspected reme halo, bulb replaced may 2020, bulb good until May 2023. 
humidifier pad recently replaced, water was not flowing, turned Piercing valve off and on, water now flowing. 
filter changed at fall maintenance, not due be changed until fall. 
spoke to customer about surge protectors, customer not interested at this time
Corey B.
Corey B. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System condenser coil is very dirty. cleaned coil. inspected reme halo, bulb replaced may 2020, bulb good until May 2023. humidifier pad recently replaced, water was not flowing, turned Piercing valve off and on, water now flowing. filter changed at fall maintenance, not due be changed until fall. spoke to customer about surge protectors, customer not interested at this time
Bridgeport, WV 26330
Bridgeport, WV - Service Call Platinum Client
upon arrival did find capacitor to be failed replaced capacitor tested unit 
pressures were 81/321 r22 system from 1991 did set lead for replace and customer is signed up on maintenance.
Kyle P.
Kyle P. Checked in
Service Call Platinum Client upon arrival did find capacitor to be failed replaced capacitor tested unit pressures were 81/321 r22 system from 1991 did set lead for replace and customer is signed up on maintenance.
Bridgeport, WV 26330