Looking for a true partner when it comes to your heating, air and plumbing needs in Grafton, WV? Connect with the team at Grogg's Home Services! Proudly serving your area since 1970, you will love our affordable prices and friendly service. Our technicians are knowledgeable and experienced, so you can rest assured that your systems are in good hands. For repairs, installations and maintenance services you can trust, Grogg's is your company!
Please check out our reviews below from clients near you in Grafton, WV. They demonstrate the commitment we have to providing exceptional customer service on every job we do each and every time.
Your professional maintenance should include the following each year:
- Replacement of air filters - To maintain airflow and quality, air filters should be changed on a regular basis.
- Assessment of thermostat settings: When you are home and using the space, the settings should keep it comfortable. When you are not home, they should be changed to save energy.
- Electrical connection check: The voltage and current readings should indicate that the connections are secure.
- Lubrication - Lubrication lowers resistance and aids in energy conservation.
- Examining the condensate drain will help to make sure that it is not blocked or clogged in any way.
- Inspection of the outdoor HVAC unit: The area around the outdoor HVAC unit should be cleared of debris and dirt.
- Fan evaluation: The fan's motor and blades need to be examined.
Tune-ups for air conditioners are a helpful service for homeowners. They recover a large portion of the AC unit's lost capacity and efficiency. Furthermore, tune-ups increase dependability by identifying issues before they result in failures.
The cost to replace a water heater ranges from $810 to $1,656, with the national average coming in at $1,217. Permit fees and carpentry work are additional expenses that may raise the overall cost of a water heater replacement by $50 to $1,500 or more. The size, location within the home, type of ventilation system, materials, and water heater type will all have an impact on the cost. Larger homes might require multiple units to supply enough hot water.
Recent Jobs and Reviews in Grafton, WV
Grafton, WV at a glance
Grogg's Heating & Air Conditioning, Inc. has completed 25 jobs in Grafton, WV between January 2022 and July 2022.
The most recent job was on July 11, 2022.
Grogg's Heating & Air Conditioning, Inc. completed its first job in Grafton, WV in July 2019.
Our Local Reviews by City
- 1, WV (2)
- Athens, OH (5)
- Belleville, WV (9)
- Belmont, WV (13)
- Belpre, OH (105)
- Belpre Township, OH (2)
- Beverly, OH (2)
- Big Bend, WV (1)
- Big Springs, WV (3)
- Blennerhassett, WV (1)
- Bridgeport, WV (118)
- Brownton, WV (1)
- Buckhannon, WV (15)
- Center Point, WV (1)
- Chesterhill, OH (1)
- Clarksburg, WV (95)
- Clay, WV (3)
- Coolville, OH (10)
- Core, WV (1)
- Cottageville, WV (2)
- Coxs Mills, WV (1)
- Cutler, OH (4)
- Davisville, WV (21)
- De Kalb-Troy, WV (1)
- Elizabeth, WV (15)
- Elkins, WV (1)
- Ellenboro, WV (1)
- Evans, WV (1)
- Fairmont, WV (52)
- Fleming, OH (1)
- Flemington, WV (4)
- Glenville, WV (2)
- Grafton, WV (8)
- Grantsville, WV (7)
- Guysville, OH (1)
- Hackers Creek-Skin Creek, WV (1)
- Harrisville, WV (8)
- Hockingport, OH (3)
- Horner, WV (1)
- I, WV (1)
- Jane Lew, WV (5)
- Kincheloe, WV (1)
- Little Hocking, OH (16)
- Lost Creek, WV (12)
- Lowell, OH (2)
- Lubeck, WV (2)
- Lumberport, WV (2)
- Mannington, WV (4)
- Marietta, OH (77)
- McConnelsville, OH (1)
- Meadowbrook, WV (2)
- Millwood, WV (6)
- Mineral Wells, WV (45)
- Moatsville, WV (4)
- Morgantown, WV (13)
- Mount Clare, WV (17)
- New Martinsville, WV (1)
- New Milton, WV (2)
- Newport, OH (3)
- North Hills, WV (2)
- Nutter Fort, WV (8)
- Paden City, WV (1)
- Parkersburg, WV (456)
- Pennsboro, WV (16)
- Philippi, WV (4)
- Portland, OH (1)
- Pullman, WV (1)
- Rachel, WV (1)
- Ravenswood, WV (54)
- Reno, OH (1)
- Reynoldsville, WV (4)
- Ripley, WV (5)
- Rivesville, WV (2)
- Rock Cave, WV (3)
- Rockport, WV (2)
- Saint Marys, WV (36)
- Salem, WV (17)
- Sandyville, WV (6)
- Second, WV (2)
- Shinnston, WV (20)
- Sistersville, WV (1)
- Smithville, WV (1)
- SOMERVLLE FRK, WV (1)
- South Urban, WV (1)
- Southern, WV (1)
- Spelter, WV (1)
- Spencer, WV (8)
- Stockport, OH (1)
- Stonewood, WV (5)
- Summit Point, WV (1)
- Sutton, WV (1)
- Tallmansville, WV (2)
- Union, WV (1)
- Vienna, WV (225)
- Vincent, OH (29)
- Walker, WV (18)
- Walkersville, WV (1)
- Wallace, WV (1)
- Washington, WV (112)
- Waterford, OH (2)
- Waverly, WV (22)
- West Augusta, WV (2)
- West Union, WV (5)
- Weston, WV (11)
- Williamstown, WV (95)
- Wolf Summit, WV (1)
Job Locations and Reviews
Evaporator coil replacement
Performed Platinum Comfort Club Membership Tune-Up on Cooling System Checked refrigerant pressures. They were low at 52 low side 198 high side. Checked capacitor and cleaned all electrical connections. Unit is an older r22 unit recommended replacement.
AC service
Performed Platinum Comfort Club Membership Tune-Up on Cooling System 2021 Goodman heat pump using propane secondary heat w/AA413 filter. Replaced filter. All checks good at this time
Performed Platinum Comfort Club Membership Tune-Up on Cooling System 2006 Rheem split system w/ AA413 filter and washable filter in bottom of blower cabinet, and using r410a refrigerant. Purchased spare filter. Gas pressure, capacitors, and amp draws in range. Cleaned flame sensor and condenser coil. Ensured proper draining. Getting good temps on line and strong air through vents inside. Customer wishes to establish Cozy Plan today. All checks good at this time. Only recommendation I would add is to consider surge protection for the units. We can provide devices directly for the furnace(120v) and a/c (240v). These will help protect equipment from unforeseen occurrences that could damage electrical components and lead to more costly repairs. CUSTOMER WOULD LIKE MAILED PHYSICAL COPY OF INVOICE. I attached her sons email as backup but most likely not to be seen there.
Service Call back customer wanted to see if adding refrigerant would make his ac work after it was running empty. It did not now customer wants a comfort adviser for a new system.
Service No Charge upon diagnosis did find that unit to be miswired Yand C for outdoor unit were landed on Y and R causing board to backfeed. originall thermostat on unit was faulty customer had thermostat new thermostat rewired and system operating normally at this time.
Performed Platinum Comfort Club Membership Tune-Up on Heating System coo read 70 ppm (is elevated ) 5.5 % 02 blower amps 5.21 inducer 1.55 blower cap tested within range pulled blower motor to inspect heat exchanger did nit find any cracks however heat exchanger is in very poor condition would suggest replacing unit before heat exchanger fails Performed Platinum Comfort Club Membership Tune-Up on Cooling System pressure were 114/229 38 degree Saturation temp capacitor tested while running tested at 39.8 /4.9 all within range no contactor cleaned coils System is from 2009 do recommend replacing system if any repair is needed did add filter size
Performed Platinum Comfort Club Membership Tune-Up on Cooling System Found faulty breaker. Reset breaker.
Plumbing maintenance
Performed Platinum Comfort Club Membership Tune-Up on Heating System both heat banks were pulling approximately 21 amps temp rise for heat banks were 35 temp rise with heatpump were 32 blower bottom amp draw ecm approximately 0.98 did not find any issues with heating customer supplies filters customer has had no issues at this time System operating properly
A.O. Smith 40 Gal Natural Gas Hot Water Tank
Aprilaire 8476 Digital Programmable Thermostat w/ Event-Based Air Cleaning replaced new thermostat in main living room.
MAIN LINE CLEAN OUT TO 100 FEET - w/Cleanup, Does Not Include Jetter Charge * STANDARD
Performed Platinum Comfort Club Membership Tune-Up on Heating System. Trane Furnace, replaced filter, cleaned cabinet and flame sensor, checked all wiring connections, checked blower motor, checked inducer motor, ran combustion analysis, gas pressure set to 3.3, system operating normally.
Service Call Platinum Client, replaced primary limit, system still short cycling, found new limit from Johnstone was defective, put old limit back in system operating normally, adjusted gas pressure from 10.5 to 9.5 inH20 and adjusted blower speed from medium low to medium high, cleaned burner orifices, they were plugged causing delayed igniton, system now has a 57 degree temperature rise, operating normally.