Don't let a surprise AC repair break the bank! Call the professional team at Grogg's for exceptional home comfort services in Little Hocking, OH. We've served the area since 1970 with honest heating, air, plumber and electrician services that go above and beyond. Our experienced technicians provide repair, replacement and maintenance services on a number of systems for your home. We also offer discounts, financing and amazing warranties on services.
Check your thermostat first. Near the bottom of your thermostat, there ought to be a switch for the fan. There are two options for the switch: ON and AUTO. The fan will continuously circulate air throughout the house when it is in the on position. As a result, you might experience cold air coming from the vents. When the switch is set to the auto position, the fan won't turn on until the air has reached the proper temperature. In order to stop cool air from being fed into your home, make sure the thermostat's fan switch is set to auto.
Next, check the air filter. If you can't recall the last time you replaced the air filter in your furnace it's likely that the filter is too dirty for the furnace to function properly. The airflow over the heat exchanger can be obstructed by a dirty air filter, which will lead to overheating. The burners will then be turned off and the high-limit switch tripped for safety reasons at this point. In order to enhance indoor air quality and avoid furnace issues, make sure to change your air filter every month.
The national average for replacing an HVAC unit is $7,000, and costs can range from $5,000 to $10,000. This equals between $25 and $60 per square foot. The size and brand of the HVAC system, the size of the house, the length of the ductwork, and the efficiency rating of the new unit all affect prices.
Mineral build-up is the tankless water heater issue that arises the most frequently. You need to watch out for mineral buildup inside your water heater whether you use a conventional or tankless model. Hard water is water with a high mineral content (as opposed to soft water), and the harder your water, the greater the risk of harmful mineral buildup.
Too many simultaneous hot water uses (such as multiple showers running) can overload your tankless water heater, depending on its capacity. If your water heater is overloaded, it might have trouble providing the necessary hot water or it might even shut off. If this occurs, you should reduce the number of simultaneous uses of hot water and you might want to think about resetting your unit.
We invite you to read some of our reviews below from your neighbors in Little Hocking, OH. They will show our dedication and commitment to providing top notch customer service with every job we do.
Recent Jobs and Reviews in Little Hocking, OH
Little Hocking, OH at a glance
Grogg's Heating & Air Conditioning, Inc. has completed 25 jobs in Little Hocking, OH between October 2019 and April 2020.
The most recent job was on April 8, 2020.
Grogg's Heating & Air Conditioning, Inc. completed its first job in Little Hocking, OH in June 2019.
Our Local Reviews by City
- 1, WV (2)
- Athens, OH (5)
- Belleville, WV (9)
- Belmont, WV (13)
- Belpre, OH (105)
- Belpre Township, OH (2)
- Beverly, OH (2)
- Big Bend, WV (1)
- Big Springs, WV (3)
- Blennerhassett, WV (1)
- Bridgeport, WV (118)
- Brownton, WV (1)
- Buckhannon, WV (15)
- Center Point, WV (1)
- Chesterhill, OH (1)
- Clarksburg, WV (95)
- Clay, WV (3)
- Coolville, OH (10)
- Core, WV (1)
- Cottageville, WV (2)
- Coxs Mills, WV (1)
- Cutler, OH (4)
- Davisville, WV (21)
- De Kalb-Troy, WV (1)
- Elizabeth, WV (15)
- Elkins, WV (1)
- Ellenboro, WV (1)
- Evans, WV (1)
- Fairmont, WV (52)
- Fleming, OH (1)
- Flemington, WV (4)
- Glenville, WV (2)
- Grafton, WV (8)
- Grantsville, WV (7)
- Guysville, OH (1)
- Hackers Creek-Skin Creek, WV (1)
- Harrisville, WV (8)
- Hockingport, OH (3)
- Horner, WV (1)
- I, WV (1)
- Jane Lew, WV (5)
- Kincheloe, WV (1)
- Little Hocking, OH (16)
- Lost Creek, WV (12)
- Lowell, OH (2)
- Lubeck, WV (2)
- Lumberport, WV (2)
- Mannington, WV (4)
- Marietta, OH (77)
- McConnelsville, OH (1)
- Meadowbrook, WV (2)
- Millwood, WV (6)
- Mineral Wells, WV (45)
- Moatsville, WV (4)
- Morgantown, WV (13)
- Mount Clare, WV (17)
- New Martinsville, WV (1)
- New Milton, WV (2)
- Newport, OH (3)
- North Hills, WV (2)
- Nutter Fort, WV (8)
- Paden City, WV (1)
- Parkersburg, WV (456)
- Pennsboro, WV (16)
- Philippi, WV (4)
- Portland, OH (1)
- Pullman, WV (1)
- Rachel, WV (1)
- Ravenswood, WV (54)
- Reno, OH (1)
- Reynoldsville, WV (4)
- Ripley, WV (5)
- Rivesville, WV (2)
- Rock Cave, WV (3)
- Rockport, WV (2)
- Saint Marys, WV (36)
- Salem, WV (17)
- Sandyville, WV (6)
- Second, WV (2)
- Shinnston, WV (20)
- Sistersville, WV (1)
- Smithville, WV (1)
- SOMERVLLE FRK, WV (1)
- South Urban, WV (1)
- Southern, WV (1)
- Spelter, WV (1)
- Spencer, WV (8)
- Stockport, OH (1)
- Stonewood, WV (5)
- Summit Point, WV (1)
- Sutton, WV (1)
- Tallmansville, WV (2)
- Union, WV (1)
- Vienna, WV (225)
- Vincent, OH (29)
- Walker, WV (18)
- Walkersville, WV (1)
- Wallace, WV (1)
- Washington, WV (112)
- Waterford, OH (2)
- Waverly, WV (22)
- West Augusta, WV (2)
- West Union, WV (5)
- Weston, WV (11)
- Williamstown, WV (95)
- Wolf Summit, WV (1)
Job Locations and Reviews
Arrived and charged system with 4lbs of 410a. System is operating properly at this time. Package unit on very steep slope right at edge of home. Two men should do work here at any given time.
Performed annual maintenance on furnace.
Noise customer heard was water in the inducer upon start up. Cleared train line and trap. Put dish soap in line to help keep clean. Installed carbon monoxide detector.
Installed new blower motor under warranty. Adjusted price per office.
Preformed standard check.
Replace failed capacitor for blower motor and changed dirty filter.
Arrived to find unit unplugged, I plugged it in and gave a call for heating. During cycle it was discovered that unit was tripping out on high temp. I adjusted gas pressure down .6†to 3.2 as well as increased speed of fan. Found several vents closed or obstructed I advised customer that ALL vents must remain very poor airflow reasons to believe duct work is part of the issue. Also dirty blower wheel as well as secondary heat exchanger, a coil probably needs cleaned
Limit switch on inducer motor was tripped from a power outage. Reset switch and unit is running.
Install new furnace and thermostat. Remove new parts just installed in furnace
Removed and replaced inducer motor, as well as pressure switch. Needs board replaced unit comes on for 1 second and faults out immediately to failed to ignite code. Customer will contact for bid or repair decision asap
Thermostat was sending a signal for heat even though temperature was above set point. Replaced thermostat. Preformed heating and cooling check. Unable to tested outlet gas pressure, tap screw has been stripped. Unit is kicking out on open limit, switched heat fan speed to black wire (high speed) to help with overheating. It did not help, system still tripping on high limit. Evaporator coil is dirty. Air conditioner uses old R22 refrigerant. Recommended replacement of heating and cooling system. Set up an estimate for tomorrow 3-5.
Removed and replaced draft inducer motor to restore heating , previously billed for service fee needs billed for this call as well
Bathroom Remodel Kevin Jones & Steve Maone
Wrong motor from Sid Harvey
Readjusted gas pressure to proper level.
Readjusted gas pressure to proper level.
Found rats nest inside top cabinet and found that the hose to the pressure switched had been chewed up by a rodent. Replaced hose and preformed heating check.
Preformed heating check. Adjusted outlet gas pressure from 7.9inwg down to 3.2inwg.
Install new furnace, ac and coi. New pad, disconnect and line set. New filter and thermostat. Modify gas, drains, electrical and flue pipes. Ed Isaly 304.834.744 cell
Arrived to find draft inducer motor seized up, with applied power drawing in excess of fla (2.8)
Installed door switch. System is operating properly at this time.
Performed annual maintenance on air handler heat pump.
Performed annual maintenance on furnace.
Arrived to find gas off at shut off
Arrived and found inducer motor full of water. Dumped water and determined door switch has failed also due to water. Will order door switch and replace once part comes in. Bypassed doorswitch for now. System is operating properly at this time.