Contact Us Call Now Request Service

Mount Clare WV Heating, AC Repair & Plumber

Looking for a true partner when it comes to your heating, air and plumbing needs in Mount Clare, WV? Connect with the team at Grogg’s Home Services! Proudly serving your area since 1970, you will love our affordable prices and friendly service. Our technicians are knowledgeable and experienced, so you can rest assured that your systems are in good hands. For repairs, installations and maintenance services you can trust, Grogg’s is your company!

Please check out our reviews below from clients near you in Mount Clare, WV. They demonstrate the commitment we have to providing exceptional customer service on every job we do each and every time.

Recent Jobs and Reviews in Mount Clare, WV

Rated 4.5 out of 5 stars based on 17 customer reviews

Mount Clare, WV at a glance

Grogg's Heating & Air Conditioning, Inc. has completed 25 jobs in Mount Clare, WV between January 2022 and April 2022.

The most recent job was on April 11, 2022.

Grogg's Heating & Air Conditioning, Inc. completed its first job in Mount Clare, WV in June 2019.

Our Local Reviews by City

Job Locations and Reviews

Mount Clare, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
Checked both air filters on both systems and replaced one down stairs. With customers own filter. Checked and cleaned all electrical connections. Tested capacitors as well. Both systems are in good running condition at this time. Plugged hole left in flue.
Doug H.
Doug H. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System Checked both air filters on both systems and replaced one down stairs. With customers own filter. Checked and cleaned all electrical connections. Tested capacitors as well. Both systems are in good running condition at this time. Plugged hole left in flue.
Mount Clare, WV 26408
Mount Clare, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System
Doug H.
Doug H. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System
Mount Clare, WV
Mount Clare, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling Syste
Did do maintenance on cooling system
Capacitor read 44.3 /5.18
Standing pressures @109@ 33 ambient 
Coils cleaned 
Contacts look to be in good order 
Do recommend adding surge protection to unit to help protect investment
Kyle P.
Kyle P. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling Syste Did do maintenance on cooling system Capacitor read 44.3 /5.18 Standing pressures @109@ 33 ambient Coils cleaned Contacts look to be in good order Do recommend adding surge protection to unit to help protect investment
Mount Clare, WV 26408
Corey B.
Corey B. Checked in
service call
Mount Clare, WV 26408
Mount Clare, WV - CLEAN EVAPORATOR COIL - 1-5 Ton, Chemical In Place * STANDARD * ALSO CONSIDER Filters
Corey B.
Corey B. Checked in
CLEAN EVAPORATOR COIL - 1-5 Ton, Chemical In Place * STANDARD * ALSO CONSIDER Filters
Mount Clare, WV 26408
Don M.
Don M. Checked in
Mount Clare, WV 26408
Nathan B.
Nathan B. Checked in
Service No Charge: home owner keeps wiping code off of tank I told him not to reset it next time so I can troubleshoot it
Mount Clare, WV 26408
Mount Clare, WV - DUAL CAPACITOR * PREMIUM AMERICAN MADE - 25/10 To 55/10 MFD, 370/440V, Oval or Round
Kyle P.
Kyle P. Checked in
DUAL CAPACITOR * PREMIUM AMERICAN MADE - 25/10 To 55/10 MFD, 370/440V, Oval or Round
Mount Clare, WV 26408
Mount Clare, WV - Service Call Platinum Client
Corey B.
Corey B. Checked in
Service Call Platinum Client
Mount Clare, WV 26408
Mount Clare, WV - Service Call Platinum Client
found flex gas line to be leaking re did gas line as well as replaced flex double leak checked nonleaks at this time used bullbe check on every joint
Kyle P.
Kyle P. Checked in
Service Call Platinum Client found flex gas line to be leaking re did gas line as well as replaced flex double leak checked nonleaks at this time used bullbe check on every joint
Mount Clare, WV
Mount Clare, WV - Service Call Platinum Client

installed new inducer motor, verified normal operation. 

spoke to customer about RGF reme halo and Halo LED. quoted pricing.
Corey B.
Corey B. Checked in
Service Call Platinum Client installed new inducer motor, verified normal operation. spoke to customer about RGF reme halo and Halo LED. quoted pricing.
Mount Clare, WV 26408
Corey B.
Corey B. Checked in
after hours service
Mount Clare, WV 26408
Mount Clare, WV - Performed Platinum Comfort Club Membership Tune-Up on Heating System
performed heating maintenance on upper garage system is over 15 years old but passed combustion analysis 
all capacitors on unit passed test
Kyle P.
Kyle P. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Heating System performed heating maintenance on upper garage system is over 15 years old but passed combustion analysis all capacitors on unit passed test
Mount Clare, WV 26408
Mount Clare, WV - Service Call Platinum Client

did preform combustion analysis numbers did read elevated did adjust gas pressure still read elevated. 
unit is 17 years of age did get quote set up for 2/8/22
Kyle P.
Kyle P. Checked in
Service Call Platinum Client did preform combustion analysis numbers did read elevated did adjust gas pressure still read elevated. unit is 17 years of age did get quote set up for 2/8/22
Mount Clare, WV 26408
Mount Clare, WV - Description of work performed for Warranty Customer

did replace inducer motor on unit parts and labor covered under warranty
Kyle P.
Kyle P. Checked in
Description of work performed for Warranty Customer did replace inducer motor on unit parts and labor covered under warranty
Mount Clare, WV 26408
Mount Clare, WV - Performed Platinum Comfort Club Membership Tune-Up on Heating System
did preform maintenance on system did find failed capacitor reading 11.0 (12.5) inducer motor was pulling high amps did recommend replacing unit if costly repair is needed.
Kyle P.
Kyle P. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Heating System did preform maintenance on system did find failed capacitor reading 11.0 (12.5) inducer motor was pulling high amps did recommend replacing unit if costly repair is needed.
Mount Clare, WV 26408
Mount Clare, WV - HVAC INSTALL
James S.
James S. Checked in
HVAC INSTALL
Mount Clare, WV 26408
Mount Clare, WV - Service No Charge

diagnosis of bad gas valve unit is under warranty/labor warranty 

pulled valve from shop stock and got customer heat adjusted gas pressures to 3,25. in 8.9inwc 

needs inducer ordered also due to bearing getting hot. will do so Monday.
Kyle P.
Kyle P. Checked in
Service No Charge diagnosis of bad gas valve unit is under warranty/labor warranty pulled valve from shop stock and got customer heat adjusted gas pressures to 3,25. in 8.9inwc needs inducer ordered also due to bearing getting hot. will do so Monday.
Mount Clare, WV 26408
Mount Clare, WV - Service Call Platinum Client

bryant super 90 in nursery did have failed heat x analyzer reached 800 ppm 
did shut unit down and bid set up 
also did collect for all 8 residential unit maintenance plan
Kyle P.
Kyle P. Checked in
Service Call Platinum Client bryant super 90 in nursery did have failed heat x analyzer reached 800 ppm did shut unit down and bid set up also did collect for all 8 residential unit maintenance plan
Mount Clare, WV 26408
Kyle P.
Kyle P. Checked in
Mount Clare, WV 26408
Mount Clare, WV - Performed Platinum Comfort Club Membership Tune-Up on Heating System Air Handler, replaced filter, customer provided, cleaned cabinet, flushed drain line, checked all wiring connections, 11.1 ohms across heat kit, inspected blower motor and wheel, 37 degree temperature rise. Heat Pump, cleaned and inspected disconnect, cleaned electrical compartment, checked all wiring connections, checked capacitor, failed 28mfd out of 35mfd +-5%, replaced capacitor, inspected fan motor and blade, tested compressor, tested defrost, pressures 60/230, system operating normally.
Dakota W.
Dakota W. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Heating System Air Handler, replaced filter, customer provided, cleaned cabinet, flushed drain line, checked all wiring connections, 11.1 ohms across heat kit, inspected blower motor and wheel, 37 degree temperature rise. Heat Pump, cleaned and inspected disconnect, cleaned electrical compartment, checked all wiring connections, checked capacitor, failed 28mfd out of 35mfd +-5%, replaced capacitor, inspected fan motor and blade, tested compressor, tested defrost, pressures 60/230, system operating normally.
Mount Clare, WV 26408
Mount Clare, WV - Service No Charge
upon arrival did find unit to be flashing a ignition lockout but unit was running. called carrier tech support to go through readings and all parameters were good. however did clean flame sensor and flame sensor plate they were corroded possibly causing an issue. ran unit for over 1 hrs 1/2 and could not get unit to go into any kind of lockout.
Kyle P.
Kyle P. Checked in
Service No Charge upon arrival did find unit to be flashing a ignition lockout but unit was running. called carrier tech support to go through readings and all parameters were good. however did clean flame sensor and flame sensor plate they were corroded possibly causing an issue. ran unit for over 1 hrs 1/2 and could not get unit to go into any kind of lockout.
Mount Clare, WV 26408
Mount Clare, WV - Performed Platinum Comfort Club Membership Tune-Up on Cooling System,  cleaned and inspected disconnect, cleaned electrical compartment, checked capacitor, inspected fan motor and blade, tested compressor, system operating normally
Dakota W.
Dakota W. Checked in
Performed Platinum Comfort Club Membership Tune-Up on Cooling System, cleaned and inspected disconnect, cleaned electrical compartment, checked capacitor, inspected fan motor and blade, tested compressor, system operating normally
Mount Clare, WV 26408
Mount Clare, WV - ervice Call Platinum Client

arrived to find system locked out due to tripped rollout. upon inspection found crack between two burners. this is a safety and potential fire hazard. condemned heat exchanger. estimate $5000-6000 to repair by replacing heat exchanger. recommend replacing unit due to age, condition, lack of maintenance by previous building owner.  scheduled estimate for today at 1pm
Corey B.
Corey B. Checked in
ervice Call Platinum Client arrived to find system locked out due to tripped rollout. upon inspection found crack between two burners. this is a safety and potential fire hazard. condemned heat exchanger. estimate $5000-6000 to repair by replacing heat exchanger. recommend replacing unit due to age, condition, lack of maintenance by previous building owner. scheduled estimate for today at 1pm
Mount Clare, WV 26408
Mount Clare, WV - Service Call back pressure switch failure to close, switch makes at 1.59 inH20 inducer motor pulling 2.5 inH20, jumped switch system started normally, replaced pressure switch, system operating normally.
Dakota W.
Dakota W. Checked in
Service Call back pressure switch failure to close, switch makes at 1.59 inH20 inducer motor pulling 2.5 inH20, jumped switch system started normally, replaced pressure switch, system operating normally.
Mount Clare, WV 26408

Undeniably Good Reviews SINCE 1970

The last home service provider you'll ever need!

Request Appointment 
Gravity Forms Pagination Must be Steps